Schneider Electric Easy UPS 3L 300kVA 400V 3:3 UPS | 5×8 Start-Up | 1-Year Warranty | E3LUPS300KHS

Easy UPS 3L 300kVA 400V 3:3 UPS provides reliable three-phase online power protection for data centers, industrial facilities and critical infrastructure. Its external battery system supports flexible backup runtime planning and scalable power protection.

130,876.00 AED

Speedy and reliable parcel delivery!

For Immediate delivery

For urgent delivery requirements, please contact our sales team. Standard shipping is typically within 2–3 days, with back-to-back orders taking 4–5 weeks. Product images are for illustrative purposes only.

Documents

Click Here For Product Data Sheet


Easy UPS 3L 300kVA 400V 3:3 UPS (E3LUPS300KHS)

The Easy UPS 3L 300kVA 400V 3:3 UPS (E3LUPS300KHS) is a high-capacity three-phase online UPS designed to provide dependable power protection and business continuity for data centers, industrial facilities, commercial buildings, electrical rooms, telecommunications infrastructure, and other mission-critical applications. With a rated capacity of 300kVA / 300kW, it provides high-power protection for demanding electrical and IT environments.

The E3LUPS300KHS operates with a 400V three-phase input and output in a 3:3 configuration. It also supports 380V and 415V configurations, providing flexibility for different electrical infrastructure requirements. The UPS uses double-conversion online technology to continuously regulate and condition the supplied power.

With a rated output of 300kVA / 300kW, the Easy UPS 3L 300kVA is designed for high-demand critical power applications. Schneider Electric specifies an input voltage range of 323V to 477V, a 40–70Hz input frequency range, and a maximum input current of 540A. Input harmonic distortion is specified at less than 3% at full load.

The UPS uses an external battery system, allowing the battery configuration and runtime to be selected according to the requirements of the installation. The specified battery voltage range is ±216V to ±300V, with lead-acid external batteries supported.

The E3LUPS300KHS includes 5×8 startup service, providing professional startup assistance as part of the product configuration. The supplied equipment includes a dust filter and installation manual.

Schneider Electric’s Smart Test mode is designed to help simplify commissioning, reduce deployment time and lower startup costs. This makes the Easy UPS 3L suitable for projects where fast and efficient deployment is important.

The Easy UPS 3L platform supports parallel and redundant configurations, providing flexibility for installations requiring increased capacity or availability. Its fault-tolerant design and scalable architecture make the E3LUPS300KHS suitable for critical power infrastructure.

The UPS features a touchscreen LCD user interface for local monitoring and control. Connectivity options include network and management interfaces, while the EcoStruxure-connected architecture allows the UPS to integrate with Schneider Electric’s broader power-management ecosystem.

The APC Easy UPS 3L 300kVA also provides strong electrical performance, with output harmonic distortion specified at less than 2% for linear loads and less than 4% for non-linear loads. Output overload capability is specified at 125% for 10 minutes and 150% for 60 seconds.

With its combination of 300kVA capacity, 400V three-phase operation, 3:3 configuration, online double-conversion technology, external battery support, Smart Test mode and 5×8 startup service, the APC Easy UPS 3L 300kVA is designed for organizations requiring reliable and scalable three-phase power protection.

Key Features

  • 300kVA / 300kW rated power
  • 400V three-phase input and output
  • 3:3 UPS configuration
  • Double-conversion online topology
  • External battery system
  • 5×8 startup service
  • Smart Test mode
  • Parallel configuration capability
  • Redundant configuration capability
  • EcoStruxure-connected architecture
  • Touchscreen LCD user interface
  • Less than 3% input harmonic distortion at full load
  • Less than 2% output harmonic distortion with linear loads
  • Less than 4% output harmonic distortion with non-linear loads
  • 125% overload for 10 minutes
  • 150% overload for 60 seconds
  • Compact tower enclosure
  • Designed for critical infrastructure

TECHNICAL SPECIFICATIONS

Click Here For Product Data Sheet

Overview
Presentation Easy-to-configure, easy-to-use and easy-to-service 300 kVA 3 phase UPS with an exceptional combination of competitive specifications, compact footprint, and highly available parallel and redundant designs. The EcoStruxure connected Schneider Electric Easy UPS 3L is the easy choice for business continuity on your shop floor or in your electrical room. Includes 5×8 start-up service.
Main
Main input voltage 400 V AC 3 phases
Other input voltage 380 V
415 V
Maximum input current 540 A
Max short time withstand current 35 kA
Input harmonic distortion Less than 3 % for full load
Load power factor 0.5 leading to 0.5 lagging without derating
Efficiency at full load 323…477 V
Input frequency 40…70 Hz
Output voltage 400 V AC 3 phases
Other output voltage 380 V
415 V
Rated power in W 300 kW
Rated power in VA 300 kVA
Maximum configurable power in VA 300 kVA
Maximum configurable power in W 300 kW
Output harmonic distortion < 2% linear load and < 4% non-linear load
Output overload operation 10 minutes at 125% and 60 seconds at 150%
UPS topology Double conversion online
Output frequency 50 Hz sync to mains
60 Hz sync to mains
Complementary
Maximum short-circuit current 35 kA
Battery type Lead-acid external
Control panel Touch screen LCD user interface
Color White (RAL 9003)
Height 197 cm
Width 60 cm
Depth 85 cm
Product weight 449 kg
USB compatible Yes
Provided equipment Dust filter
Installation manual
Start-up service
Range of product Easy UPS 3L
Product or component type Uninterruptible power supply (UPS)
Environment
Product certification CE
EAC
RCM
Ambient air temperature for operation 0…30 °C
Ambient air temperature for storage -25…55 °C
Storage altitude 0…14999.8 m
IP protection IP20
Relative humidity 0…95 % non-condensing
Storage relative humidity 0…95 % non-condensing
Acoustic level 70 dB
Heat dissipation 59386 Btu/h
Operating altitude 0…4921 ft
Batteries & Runtime
Battery type External battery system
Battery voltage +/- 216…+/- 300 V
Discharge battery voltage +/- 172.8…+/- 240 V
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 2117 mm
Package 1 Width 1000 mm
Package 1 Length 800 mm
Package 1 Weight 503 kg
Contractual warranty
Warranty (in months) 12

Product Highlights

APC Easy UPS 3L 300kVA – High-Capacity Power Protection for Critical Infrastructure

The APC Easy UPS 3L 300kVA 400V 3:3 UPS (E3LUPS300KHS) is designed for large commercial, industrial and data-center environments where power continuity is fundamental to operations. Delivering 300kVA / 300kW of output capacity, this three-phase online UPS provides a substantial power-protection platform for critical electrical and IT infrastructure.

With 400V three-phase input and output, double-conversion online topology, parallel capability and external battery architecture, the Easy UPS 3L is designed to provide a dependable layer between the utility supply and sensitive loads. The configuration includes 5×8 startup service, dust filters and installation documentation.

Online Double-Conversion Protection

The UPS uses double-conversion online technology, continuously converting and regenerating power before supplying it to connected equipment. This architecture is appropriate where power quality is as important as backup availability.

The system supports up to 125% overload for 10 minutes and 150% for 60 seconds, providing additional operating headroom for appropriately sized installations.

300kVA Capacity for Large Installations

At 300kVA, this is infrastructure-scale power protection rather than a conventional office UPS. It can form part of power-continuity architecture supporting data centers, industrial facilities, telecommunications infrastructure and other high-demand environments.

The system supports parallel operation, allowing appropriately designed installations to increase capacity or build redundancy.

Designed for Demanding Environments

Replaceable dust filters help protect the UPS in harsher operating environments, while the wide input-voltage window helps preserve battery capacity for actual power outages rather than using the batteries unnecessarily for every input fluctuation.

The LCD touchscreen provides access to operating information, system parameters and alarms.

Dubai & UAE 

For businesses in Dubai, Abu Dhabi, Sharjah and other UAE commercial and industrial centers, high-capacity UPS systems can be an important component of data-center, manufacturing, healthcare, telecommunications and commercial power-continuity planning.

Dubai’s concentration of data centers, commercial facilities and high-density IT infrastructure makes properly engineered three-phase UPS protection particularly relevant. Buyers should ensure that electrical installation, battery configuration, bypass arrangements and commissioning are designed by appropriately qualified professionals.

OMA Computers can supply this APC UPS for UAE requirements, with shipping available across the UAE. For a 300kVA installation, buyers should confirm site requirements, delivery access, commissioning and installation arrangements before ordering.

Key Specifications

  • Brand: APC
  • Model: E3LUPS300KHS
  • Capacity: 300kVA / 300kW
  • Input: 400V 3-phase
  • Output: 400V 3-phase
  • Topology: Online double conversion
  • Battery: External battery system
  • Parallel Capability: Yes
  • Control: LCD touchscreen
  • Startup Service: 5×8
  • Warranty: 1-year on-site repair or replacement with authorized startup service

Is It Right for You?

The E3LUPS300KHS is intended for organizations that need large-scale three-phase power protection, not ordinary office backup. It is particularly relevant to data centers, industrial facilities and critical commercial infrastructure requiring high-capacity online UPS protection.