InRow RD 600mm Air Cooled | Up to 42kW | 380–415V 3-Phase | ACRD602
The InRow RD 600mm Air Cooled (ACRD602) is a high-density precision cooling unit designed for data centers and IT environments requiring efficient, targeted cooling. It provides cooling capacity of up to 42kW and is designed for row-based installation alongside server racks.
The ACRD602 operates with a 380–415V three-phase power supply at 50/60Hz and uses an air-cooled design with horizontal airflow. It features a VFD brushless scroll compressor with R-410A refrigerant and specified power consumption of 9.5kW.
The unit supports humidification and reheat options and provides network management and temperature monitoring capabilities. Its 600mm-wide floor-standing design is suitable for high-density data center cooling applications.
- Up to 42kW cooling capacity
- 600mm width
- Air-cooled design
- 380–415V three-phase operation
- 50/60Hz frequency
- VFD brushless scroll compressor
- R-410A refrigerant
- 9.5kW specified power consumption
- Horizontal airflow pattern
- Humidification and reheat option
- Network interface
- Temperature monitoring
- Touch-screen GUI
- Floor-standing design
97,833.00 AED
- 2 to 3 days-delivery
Speedy and reliable parcel delivery!
For Immediate delivery
For urgent delivery requirements, please contact our sales team. Standard shipping is typically within 2–3 days, with back-to-back orders taking 4–5 weeks. Product images are for illustrative purposes only.
Request a Quote
Documents
Click Here For Product Data Sheet
InRow RD 600mm Air Cooled (ACRD602)
The InRow RD 600mm Air Cooled (ACRD602) is a high-density precision cooling unit designed for data centers and IT environments where targeted thermal management is required. The unit provides cooling capacity of up to 42kW and is designed for row-based cooling applications where conditioned air is delivered close to the IT equipment.
The ACRD602 operates with a 380–415V three-phase electrical supply and supports 50Hz and 60Hz operating frequencies. This configuration is suitable for compatible data center electrical infrastructures requiring three-phase precision cooling.
The unit uses an air-cooled architecture with a horizontal airflow pattern. The row-based design captures heated air from the IT environment and supplies conditioned air toward the server racks, helping minimize air mixing and improve cooling predictability.
The ACRD602 incorporates a VFD brushless scroll compressor and uses R-410A refrigerant. The variable-frequency-drive compressor is designed to adjust cooling operation according to the thermal load, supporting efficient operation across varying cooling requirements.
The unit has a specified 9.5kW power consumption and is designed for high-energy-efficient operation. Its cooling system can operate across varying capacity requirements to maintain appropriate rack inlet temperatures and help manage operational energy consumption.
The ACRD602 provides an optional humidification and reheat function. These options can provide additional environmental-control capabilities for data center installations where temperature and humidity conditions need to be managed more precisely.
The cooling unit features active airflow control and active response control. These functions monitor and adjust airflow and cooling capacity to help maintain appropriate server inlet temperatures and provide visibility into the operating condition of the cooling system.
The unit incorporates electronically commutated fans designed to match airflow requirements with the data center heat load. It also features direct-drive motors, air filtration, fault-tolerant fan operation and field-replaceable fans and electronics components.
The ACRD602 supports network management through a network interface, allowing the cooling unit to be connected to a network for monitoring and management. It also provides temperature display, real-time capacity monitoring and a touch-screen graphical user interface for local operation and monitoring.
The unit is designed for compatibility with rack and hot-aisle containment systems. Its row-based architecture positions cooling close to the heat load, while containment compatibility can help reduce the mixing of hot and cold air within the data center environment.
The ACRD602 has a compact 600mm-wide enclosure with dimensions of approximately 1991mm high × 600mm wide × 1070mm deep. Its net weight is approximately 391kg, while the packaged unit weighs approximately 436kg. ([boxxe.com](https://boxxe.com/shop/computers-and-peripherals/computer-components/chassis-components/rack-cooling-equipment/acrd602-apc-acrd602-computer-cooling-system-part-accessory?utm_source=chatgpt.com))
The floor-standing design provides flexibility for installation within server rows, while casters allow the unit to be moved into position where required. Front service access is designed to simplify routine maintenance and servicing.
The ACRD602 combines high-density cooling capacity, variable-speed compressor technology, efficient airflow management, network monitoring and optional humidity control to provide a precision cooling solution for demanding data center and IT infrastructure environments.
Key Features
- Up to 42kW cooling capacity
- 600mm-wide InRow cooling design
- Air-cooled precision cooling
- 380–415V three-phase operation
- 50/60Hz operating frequency
- VFD brushless scroll compressor
- R-410A refrigerant
- 9.5kW specified power consumption
- Horizontal airflow pattern
- Active airflow control
- Active response control
- Electronically commutated fans
- Fault-tolerant fan system
- Field-replaceable fans and electronics module
- Humidification and reheat option
- Network interface
- Real-time capacity monitoring
- Rack inlet temperature control
- Temperature display
- Touch-screen GUI
- Rack and hot-aisle containment compatibility
- Front service access
- Floor-standing design
- Approximately 1991 × 600 × 1070mm dimensions
- Approximately 391kg net weight