InRow RC 600mm Chilled Water | Up to 70kW | 380–415V 3-Phase | ACRC602P

The InRow RC 600mm Chilled Water with Humidifier (ACRC602P) is a high-capacity precision cooling unit designed for data centers and IT environments requiring efficient row-based cooling. It provides cooling capacity of up to 70kW and is designed for high-density applications.

The ACRC602P operates on 380–415V three-phase power at 50/60Hz and uses a chilled-water cooling architecture. The unit is designed with a 600mm-wide enclosure and supports horizontal air discharge with rear air intake.

The model includes humidification and reheat functionality and features an integrated network card with TLS 1.3 security. It has specified input power of approximately 15kW and supports network management and real-time cooling monitoring.

  • Up to 70kW cooling capacity
  • 600mm-wide design
  • Chilled-water cooling
  • 380–415V three-phase operation
  • 50/60Hz frequency
  • Humidifier included
  • Reheat functionality
  • 3.3kW cooling-system power specification
  • 15kW maximum input power for humidifier/reheat configuration
  • Integrated network card
  • TLS 1.3 security
  • Horizontal air discharge
  • Rear air return
  • 42U rack-height compatibility
  • Floor-standing design

100,350.00 AED

Speedy and reliable parcel delivery!

For Immediate delivery

For urgent delivery requirements, please contact our sales team. Standard shipping is typically within 2–3 days, with back-to-back orders taking 4–5 weeks. Product images are for illustrative purposes only.

Documents

Click Here For Product Data Sheet


InRow RC 600mm Chilled Water with Humidifier (ACRC602P)

The InRow RC 600mm Chilled Water with Humidifier (ACRC602P) is a high-capacity precision cooling unit designed for data centers and IT environments requiring targeted thermal management. It provides cooling capacity of up to 70kW and is designed for high-density row-based cooling applications.

The ACRC602P operates with a 380–415V three-phase electrical supply and supports 50Hz and 60Hz operation. This configuration allows the unit to be integrated into compatible three-phase data center electrical infrastructures.

The cooling system uses a chilled-water architecture, allowing heat to be transferred from the IT environment through the chilled-water circuit. The 600mm-wide InRow design places the cooling equipment directly within the server row to provide targeted cooling close to the IT heat load.

The ACRC602P provides up to 70kW of cooling capacity. The platform is designed for high-density data center applications where conventional perimeter cooling may not provide sufficient cooling directly at the rack level.

The unit features variable-speed fans designed to adjust airflow according to the cooling requirement. This allows the cooling system to operate according to changing IT loads while helping reduce energy consumption during lower-load conditions.

The ACRC602P is specifically equipped with humidification and reheat functionality. These capabilities allow the unit to provide additional temperature and humidity control for data center environments where environmental conditions need to be maintained within defined operating parameters.

The product features an integrated network card with TLS 1.3 security. Network connectivity enables remote monitoring and management of the cooling system and provides access to operating information within compatible data center management environments.

The ACRC602P supports real-time cooling capacity monitoring, predictive fault notification and rack inlet temperature control. These functions help operators monitor cooling performance and respond to changing thermal conditions within the IT environment.

The unit supports remote temperature sensors for monitoring IT equipment inlet temperatures. This allows cooling operation to be controlled according to conditions at the rack level rather than relying solely on measurements at the cooling unit.

The ACRC602P incorporates factory-installed condensate management and a condensate pump to assist with removal of condensate generated during operation. The design also includes casters to facilitate positioning of the cooling unit during installation.

The unit provides top or bottom access for piping and electrical connections, providing installation flexibility within data center layouts. Dual A-B power inputs are also supported for additional power redundancy and protection.

The ACRC602P has a nominal enclosure size of approximately 1991mm high × 600mm wide × 1070mm deep. The product is designed for a 42U rack-height environment and uses a floor-standing, non-rack-mountable configuration. :contentReference[oaicite:1]{index=1}

The product data specifies a maximum airflow of approximately 2831.7 L/s, a minimum chilled-water inlet temperature of 7°C and a condensate pump flow of approximately 0.03m³/h. :contentReference[oaicite:2]{index=2}

The ACRC602P combines high-density chilled-water cooling, variable-speed airflow management, integrated humidification and reheat, network connectivity with TLS 1.3 security and rack-level temperature monitoring to provide a comprehensive precision cooling solution for demanding data center environments.

Key Features

  • Up to 70kW cooling capacity
  • 600mm-wide InRow cooling design
  • Chilled-water cooling architecture
  • 380–415V three-phase operation
  • 50/60Hz operating frequency
  • Humidification function
  • Reheat functionality
  • Variable-speed fans
  • Real-time cooling capacity monitoring
  • Predictive fault notification
  • Rack inlet temperature control
  • Remote IT equipment temperature sensing
  • Integrated network card
  • TLS 1.3 network security
  • Top or bottom piping and electrical access
  • Dual A-B power inputs
  • Factory-installed condensate pump
  • Casters for positioning
  • Horizontal air discharge
  • Rear air return
  • 42U rack-height compatibility
  • Approximately 2831.7 L/s maximum airflow
  • Approximately 1991 × 600 × 1070mm dimensions
  • Floor-standing installation